CasaFan

Axial wall fan CasaFan EQ EX ATEX M 230 V

axial wall-mounted fan in various sizes

230 V alternating current

not compatible with speed controllers

ATEX certified motor

IP55 protection from water jets


Item number 93568

delivery time up to 30 days

if(!document.getElementById('paypal-smart-payment-script')) { var script = document.createElement("script"); script.type = "module"; script.id = "paypal-smart-payment-script"; script.src = "https://cdn02.plentymarkets.com/wzjm2a03n3t8/plugin/10/paypal/js/smartPaymentScript.min.js"; script.setAttribute("data-client-id", "AZoL3Ix0BpgeWCbr0zWOZfvOkWlifQY8U5H44vzL8NikVKb40WyEv6PKdoegnf-I3eekMNmi-7r7zNUN"); script.setAttribute("data-currency", "GBP"); script.setAttribute("data-client-token", "eyJicmFpbnRyZWUiOnsiYXV0aG9yaXphdGlvbkZpbmdlcnByaW50IjoiNjI3NGU2ODM2NzgxMDE4YzVmYWNmMDFhNjU3MjhhMzEzZTg3NmU5NGE2YWYzYzA3MjFmMDA5Yzg2OTgwNWI1ZHxtZXJjaGFudF9pZD1yd3dua3FnMnhnNTZobTJuJnB1YmxpY19rZXk9ajJmYzJqcHhkZzZ2cDg0ZiZjcmVhdGVkX2F0PTIwMjQtMDQtMjBUMTU6MDg6MDAuNTk2WiIsInZlcnNpb24iOiIzLXBheXBhbCJ9LCJwYXlwYWwiOnsiaWRUb2tlbiI6bnVsbCwiYWNjZXNzVG9rZW4iOiJBMjFBQU91cG5tVWhOQXVTUWxibDN0U2JQMlo0NVd0RGdJRkdqQV80Q3R6dWh3aUVaSi1DVmoxaEkyWkpFYnI4Y2N4ZUVIWm9pekJVbW1tRjBZaXhtZHBPTGtoNzk2N293In19"); script.setAttribute("data-append-trailing-slash", ""); script.setAttribute("data-locale", "en_GB"); document.body.appendChild(script); } else { var script = document.getElementById('paypal-smart-payment-script'); script.setAttribute("data-client-id", "AZoL3Ix0BpgeWCbr0zWOZfvOkWlifQY8U5H44vzL8NikVKb40WyEv6PKdoegnf-I3eekMNmi-7r7zNUN"); script.setAttribute("data-currency", "GBP"); script.setAttribute("data-client-token", "eyJicmFpbnRyZWUiOnsiYXV0aG9yaXphdGlvbkZpbmdlcnByaW50IjoiNjI3NGU2ODM2NzgxMDE4YzVmYWNmMDFhNjU3MjhhMzEzZTg3NmU5NGE2YWYzYzA3MjFmMDA5Yzg2OTgwNWI1ZHxtZXJjaGFudF9pZD1yd3dua3FnMnhnNTZobTJuJnB1YmxpY19rZXk9ajJmYzJqcHhkZzZ2cDg0ZiZjcmVhdGVkX2F0PTIwMjQtMDQtMjBUMTU6MDg6MDAuNTk2WiIsInZlcnNpb24iOiIzLXBheXBhbCJ9LCJwYXlwYWwiOnsiaWRUb2tlbiI6bnVsbCwiYWNjZXNzVG9rZW4iOiJBMjFBQU91cG5tVWhOQXVTUWxibDN0U2JQMlo0NVd0RGdJRkdqQV80Q3R6dWh3aUVaSi1DVmoxaEkyWkpFYnI4Y2N4ZUVIWm9pekJVbW1tRjBZaXhtZHBPTGtoNzk2N293In19"); script.setAttribute("data-append-trailing-slash", ""); script.setAttribute("data-locale", "en_GB"); }
if (typeof paypal_plenty_sdk === 'undefined' || typeof renderPayPalButtons !== 'function') { document.addEventListener('payPalScriptInitialized', () => { renderPayPalButtons('6623e3080b479', 'paypal', 'buynow', 'rect', 'gold'); }); } else { renderPayPalButtons('6623e3080b479', 'paypal', 'buynow', 'rect', 'gold'); }

* Incl. VAT excl. Shipping

Dimensions and technical details

  • 230 Volt ~ 50 Hertz
  • Various options available
  • Housing colour: black
  • Housing material: non-corroding die wall panel, galvanised steel sheet, powder-coated
  • Speed levels: 1 (EQ EX ATEX fans must not be used with speed controllers / step transformers)
  • Temperature for continuous operation: -20°C to +40°C
  • Protection code: IP55
  • Insulation class: I
  • Ball-bearing ATEX-certified motor, certification by CESI, certification number CESI 03 ATEX 251, Motor EX d IIC - T4 (135°C)
  • Reversible via external reversing switch (not included in the delivery), performance in reverse ca. 67%
  • Statically and dynamically balanced impeller made from antistatic polymer
  • Mounting options: in any position, easy access to electric terminaly box
  • Application: extraction of air directly to the outside (external shutter flap sold separately) or extraction of air through ducts and ventilation shafts
  • Use in zones 1 and 2:
    • Zone 1: A place in which an explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapour or mist is likely to occur in normal operation occasionally.
    • Zone 2: A place in which an explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapour or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only.
Model Power (W) Current consumption (A) Speed (rpm) Airflow (m³/h) Total pressure Pmax (Pa) Sound pressure Lp-2m (dB(A)) Weight (kg)
EQ 25/4 M II 2G c IIB 120 0.7 1460 900 98 55 10
EQ 30/4 M II 2G c IIB 140 0.7 1400 1500 118 59 11
EQ 35/4 M II 2G c IIB 160 0.8 1350 2250 98 62 12
EQ 40/4 M II 2G c IIB 180 0.85 1290 2900 88 65 12.5
EQ 50/4 M II 2G c IIB 210 1.0 1200 4500 137 70 14.5

Dimensions ATEX EQ M fan range

Model Nominal size mm A mm B mm C mm D mm E mm F mm G mm Ø H mm
EQ 25/4 M II 2G c IIB 250 190 66 9 8 260 340 325 8.3
EQ 30/4 M II 2G c IIB 300 190 75 9 10 312 390 375 8.3
EQ 35/4 M II 2G c IIB 350 190 85 10 12 365 460 439 12.3
EQ 40/4 M II 2G c IIB 400 190 85 10 12 415 510 490 12.3
EQ 50/4 M II 2G c IIB 500 190 101 10 15 515 630 610 12.3